In municipal and industrial wastewater treatment plants (WWTPs), nitrification failure is often blamed on low dissolved oxygen, insufficient sludge age, or toxic shocks. However, in a large percentage of cases, the real root cause is far more fundamental: alkalinity depletion and buffering failure.
When alkalinity is insufficient, pH begins to drift downward. Once the buffering capacity collapses, nitrifying bacteria lose activity rapidly — and ammonia breakthrough follows.

Alkalinity vs pH: Why Buffering Capacity Matters More Than Instant Readings
Many plants continuously monitor pH but rarely track alkalinity with the same discipline.
- pH reflects the current hydrogen ion concentration.
- Alkalinity reflects the system’s ability to resist pH change — its acid-neutralizing capacity.
Alkalinity is measured as mg/L as CaCO₃ by titration to pH 4.5. In municipal wastewater, alkalinity typically consists of:
- Bicarbonate (HCO₃⁻) — dominant fraction
- Carbonate (CO₃²⁻)
- Hydroxide (OH⁻)
Because nitrification generates acidity, alkalinity acts as the primary defense mechanism against biological system instability.
Key principle:
pH is a symptom indicator. Alkalinity is a stability indicator.
The Stoichiometry of Nitrification: Why Collapse Happens Faster Than Expected
Nitrification consumes alkalinity according to fixed reaction chemistry:
- 1 mg NH₄⁺-N oxidized consumes ~7.14 mg alkalinity (as CaCO₃)
- 1 g BOD₅ removed consumes ~0.3 g alkalinity
In high-ammonia influent conditions, this demand is substantial. For example:
If influent NH₄⁺-N = 40 mg/L
→ Alkalinity consumption ≈ 286 mg/L
Many municipal influents only contain 200–300 mg/L alkalinity. Without supplementation, the system will inevitably acidify.
Risk factors include:
- High SRT full nitrification systems
- Wet-weather dilution reducing influent alkalinity
- Industrial wastewater with low buffering capacity
- Simultaneous chemical phosphorus removal
Once residual alkalinity drops below critical levels, pH decline accelerates rapidly.
Critical Control Targets for Stable Activated Sludge Nitrification
Based on full-scale plant performance data:
Optimal nitrification pH range: 6.8–8.2
Warning thresholds:
- pH < 6.5 → nitrification rate declines
- pH ≈ 6.0 → nitrification nearly stops
Recommended alkalinity control targets:
- Influent alkalinity ≥ 1.5 × theoretical nitrification demand
- Maintain residual alkalinity 50–150 mg/L (minimum)
- Sensitive nutrient removal systems: 200–300 mg/L residual
When alkalinity becomes limiting, operators may observe:
- Rising effluent ammonia
- Nitrite accumulation
- Increasing SVI (>150 mL/g)
- Filamentous overgrowth
- Lower morning pH values
- Adequate DO but poor ammonia removal
This is not an oxygen problem — it is a buffering problem.
Practical Alkalinity Supplementation Strategies
When natural influent alkalinity is insufficient, chemical supplementation becomes necessary.
Common Alkalinity Sources
| Chemical | Strength | Operational Notes |
|---|---|---|
| Sodium hydroxide (NaOH) | Strong, fast response | Higher cost, rapid pH shift risk |
| Sodium carbonate (Na₂CO₃) | Moderate | Safer buffering action |
| Lime (Ca(OH)₂) | Economical | Slurry handling & scaling risk |
| Magnesium hydroxide | Slow-release buffering | Lower overfeed risk |
Best practice:
Dose based on ammonia load, not solely on pH setpoint control.
Optimal Injection Locations
- Return activated sludge (RAS) line
- Influent channel prior to aeration
- Equalization basin
Avoid localized high-pH shock in aeration tanks.
Control Philosophy
Reactive control (wait for low pH alarm) is often too late.
Proactive strategies include:
- Routine alkalinity testing (≥3 times/week)
- Feed-forward dosing based on NH₄⁺ load
- Residual alkalinity setpoint (e.g., 100 mg/L minimum)
- SCADA-integrated alkalinity-ammonia control loops
Integrated Nutrient Removal Considerations
In BNR systems, alkalinity management becomes more complex.
Impact on EBPR
- pH < 7 reduces PAO competitiveness
- GAOs become more dominant
- Biological phosphorus removal efficiency declines
Chemical Phosphorus Removal
Ferric and aluminum salts consume additional alkalinity, further increasing buffering demand.
Thus, nitrification stability, phosphorus removal, and alkalinity control are interconnected — not independent variables.
Engineering and Operational Recommendations
To prevent nitrification collapse long-term:
- Design influent alkalinity ≥ 200 mg/L (municipal baseline)
- Provide alkalinity storage capacity for multiple days
- Size dosing systems for peak ammonia loads
- Monitor alkalinity trends — not just spot values
- Prepare seasonal adjustment strategies
Remember:
- pH tells you the current condition
- Alkalinity predicts future stability
Most nitrification collapses are not sudden events — they are the final stage of gradual alkalinity depletion.
Stable nitrification is not achieved by increasing aeration alone. It is maintained by protecting the buffering capacity of the biological system.